{
  "$schema": "https://a2a-protocol.org/schemas/agent-card.json",
  "name": "Hazem Mensi Process Engineering Agent",
  "version": "1.0.0",
  "description": "Autonomous Chemical Process Engineering agent representing Hazem Mensi. Specializes in Aspen HYSYS steady-state & dynamic simulations, API 520/521 flare network hydraulics, acid gas treating (AGRU) solvent optimization, and verified AspenTech credentials.",
  "url": "https://www.hazemensi.com",
  "provider": {
    "name": "Hazem Mensi",
    "url": "https://www.hazemensi.com",
    "email": "Hazem.Mensi@insat.ucar.tn"
  },
  "supportedInterfaces": [
    {
      "url": "https://www.hazemensi.com/api/a2a",
      "serviceUrl": "https://www.hazemensi.com/api/a2a",
      "protocolBinding": "HTTP+JSON",
      "protocol": "HTTP+JSON",
      "protocolVersion": "1.0"
    }
  ],
  "capabilities": {
    "streaming": false,
    "pushNotifications": false,
    "extendedAgentCard": false
  },
  "defaultInputModes": [
    "application/json",
    "text/plain"
  ],
  "defaultOutputModes": [
    "application/json",
    "text/plain"
  ],
  "skills": [
    {
      "id": "skill-flare-depressuring",
      "name": "Dynamic Depressuring & Flare Network Sizing (API 520/521)",
      "description": "Evaluate emergency blowdown, staggered zone depressuring to 50% design pressure within 15 minutes per API 521, flare network backpressure in Aspen Flare System Analyzer (FLARENET), and thermal radiation limits.",
      "tags": [
        "flare-systems",
        "api-521",
        "api-520",
        "hysys-dynamics",
        "plant-safety",
        "depressuring"
      ],
      "inputModes": [
        "application/json",
        "text/plain"
      ],
      "outputModes": [
        "application/json",
        "text/plain"
      ],
      "examples": [
        "Size blowdown orifices to achieve 50% DP in 15 minutes per API 521",
        "Verify backpressure on balanced bellows PSVs in Marsa El Brega flare network"
      ]
    },
    {
      "id": "skill-agru-solvent-optimization",
      "name": "Amine Sweetening & AGRU Solvent Optimization",
      "description": "Model acid gas treating units in BR&E ProMax and Aspen HYSYS, optimizing MDEA/piperazine solvent blends to meet sales gas specs (< 2.0 mol% CO2) while minimizing stripper reboiler duty within the 0.45 mol/mol rich loading safety envelope.",
      "tags": [
        "agru",
        "amine-sweetening",
        "carbon-capture",
        "promax",
        "hysys",
        "mdea-piperazine"
      ],
      "inputModes": [
        "application/json",
        "text/plain"
      ],
      "outputModes": [
        "application/json",
        "text/plain"
      ],
      "examples": [
        "Optimize MDEA/piperazine ratio for 1.86 mol% CO2 at Nawara CPF",
        "Reduce amine stripper reboiler duty to 3500 kW under pipeline delivery constraints"
      ]
    },
    {
      "id": "skill-cryogenic-dche-retrofit",
      "name": "Direct Contact Heat Exchanger (DCHE) Column Retrofit",
      "description": "Hydraulic rating and packing revamp of direct contact cooling columns using Sulzer Sulcol, KG-Tower, and Aspen Plus with high-performance packings (FLEXIPAC HC 2Y, MellapakPlus 252.Y) to reduce pressure drop by 85% and maximize flooding margins.",
      "tags": [
        "dche",
        "heat-exchanger",
        "cryogenics",
        "column-internals",
        "sulzer-sulcol",
        "kg-tower"
      ],
      "inputModes": [
        "application/json",
        "text/plain"
      ],
      "outputModes": [
        "application/json",
        "text/plain"
      ],
      "examples": [
        "Benchmark FLEXIPAC HC 2Y vs MellapakPlus 252.Y for cryogenic DCHE column revamp",
        "Calculate pressure drop reduction and flooding margin headspace"
      ]
    },
    {
      "id": "skill-flow-assurance-multiphase",
      "name": "Multiphase Flowline Hydraulics & PMC Audit",
      "description": "Gathering line multiphase hydraulics in SLB PIPESIM, slug catcher surge reception in Aspen HYSYS Dynamics, thermodynamic hydrate inhibition envelopes, and API 12J / 14E engineering review.",
      "tags": [
        "flow-assurance",
        "pipesim",
        "slugging",
        "slug-catcher",
        "hydrate-inhibition",
        "api-12j"
      ],
      "inputModes": [
        "application/json",
        "text/plain"
      ],
      "outputModes": [
        "application/json",
        "text/plain"
      ],
      "examples": [
        "Audit EPC separator sizing calculations against API 12J and GPSA Section 7",
        "Model topside slug catcher liquid surge reception in HYSYS Dynamics"
      ]
    },
    {
      "id": "skill-credential-verification",
      "name": "AspenTech & Academic Credential Verification",
      "description": "Cryptographic and official registry verification of Hazem Mensi's AspenTech Certified Expert User credential (CERT00016555), Shell & Tube Exchanger certification (CERT00017116), Carbon Capture certifications, and INSAT degree.",
      "tags": [
        "credential-verification",
        "aspentech",
        "hysys-certified-expert",
        "iso-14040",
        "insat"
      ],
      "inputModes": [
        "application/json",
        "text/plain"
      ],
      "outputModes": [
        "application/json",
        "text/plain"
      ],
      "examples": [
        "Verify AspenTech Certified Expert User credential ID cb1c6c8f-da5a-4bd1-92bd-e08479146c60",
        "Retrieve official PDF certificates and credential metadata"
      ]
    }
  ]
}
